Environmental Issues
Public registers
POEO Public Register
Licences, applications and notices search
Penalty notices search
Enforceable undertakings search
Enforceable undertakings media releases
Exemptions and approvals search
Prosecutions or civil proceedings search
Terms of use: POEO public register
Licensing FAQs
List of licences
Unlicensed premises regulated by the EPA
Contaminated land record of notices
About the record of notices
List of notified sites
Tips for searching
Disclaimer
Dangerous goods licences
Pesticide licences
Radiation licences
Home
Public registers
POEO Public Register
Licences, applications and notices search
Non-Compliance detail
Summary
Licence number:
1389
Annual Return Start:
01 May 2007
Annual Return End:
30 Apr 2008
Date Received:
26 Jun 2008
Licence Condition number
Type of non-compliance
EPA actions
No. of times occurred
L3.1
Arsenic above ANZECC 2000 trigger value of 24 ug/L (95% level of protection, slightly too moderately disturbed systems) at location LDP1.
PRP to address non-compliance(s) issued
10
L3.1
Electric Conductivity above ANZECC 2000 guideline trigger value of 350 us/cm (95% level of protection, slightly too moderately disturbed systems) at location LDP1.
PRP to address non-compliance(s) issued
12
L3.1
Nickel above ANZECC 2000 trigger value of 11 ug/L (95% level of protection, slightly too moderately disturbed systems) at location LDP1.
PRP to address non-compliance(s) issued
12
L3.1
Zinc above ANZECC 2000 trigger value of 8 ug/L (95% level of protection, slightly too moderately disturbed systems) at location LDP1.
PRP to address non-compliance(s) issued
12
L3.1
Electric Conductivity above ANZECC 2000 guideline trigger value of 350 us/cm (95% level of protection, slightly too moderately disturbed systems) at location LDP3.
PRP to address non-compliance(s) issued
7
L3.1
Total suspended solids (TSS) above licence limit at LDP3 due to lack of retention time after rainfall events.
PRP to address non-compliance(s) issued
5
L3.1
Turbidity above licence limit at location LDP3 due to lack of retention time after rainfall events.
PRP to address non-compliance(s) issued
3
L3.1
pH above licence limit at location LDP3. Exact cause unknown, possibly related to rainfall events
PRP to address non-compliance(s) issued
2
L3.1
Electric Conductivity above ANZECC 2000 guideline trigger value of 350 us/cm (95% level of protection, slightly too moderately disturbed systems) at location LDP4.
PRP to address non-compliance(s) issued
4
L3.1
Electric Conductivity above ANZECC 2000 guideline trigger value of 350 us/cm (95% level of protection, slightly too moderately disturbed systems) at location LDP5.
PRP to address non-compliance(s) issued
12
L3.1
Discharge volume exceed licence limit at location LDP5. Significant rainfall was recorded prior to and during the incidents.
PRP to address non-compliance(s) issued
8